<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-02 05-16-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 55 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 15312 7,4255
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,65 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 7,4255 Acquired: 2025/04/02 5.14.59 Total samples: 15312 Equivalent time: 0:12:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,5 dBr MIN: 3,3 dBr AVE: 4,65 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2025/04/02 5.14.59) 05.02 05.04 05.06 05.08 05.10 05.12 05.14 0 2 4 6 Pm [dBr]